ÖLFLEX. LIFT F are cold flexible PVC flat cables for flexible use under medium mechanical load conditions. They are amongothers designed for use in dry, damp and wet rooms. Outdoor is use temporarily possible, considering the temperaturerange. At room temperature they are widely resistant to certain oils and resistant to acids. Continuous operational movements,restricted guidance, usage of these cables in moving cable carriers or on motor drum guidance or under a tensilestrain of more than 15 N / mm² is not allowed.Application range: Conveyor and hoist equipments, transport installations, supply lines for moving machine parts, indoorcranes, high rack facilitiescan be used as elevator control cable up to 35 m suspension length with a maximum travel speed of 1.6 m / secDesign:based on DIN EN 50214 resp. VDE 0283-2Conductor: acc. to IEC 60228 resp. VDE 02951,0 mm2: fine wire strands of bare copper, class 51,5 - 6 mm2: extra fine wire strands of bare copper, class 6. 10 mm2: fine wire strands of bare copper , class 5Core insulation: PVC-compound TI2 acc. to DIN EN 50363-3 resp. VDE 0207-363-3Core identification acc. to VDE 0293-1, with or without GN/YE ground conductorup to 5 cores coloured in acc. to DIN VDE 0293-308starting at 6 cores: Black cores with white numbersacc. to DIN EN 50334 resp. VDE 0293-334Outer sheath: up to 1,0 mm2:PVC-compound TM2 acc. DIN EN 50363-4-1 resp. 0207-363-4-1starting at 1,5 mm2:PVC compound TM4 (cold flexible) acc. to DIN EN 50363-4-1 resp. VDE 0207-363-4-1Colour: black, similar RAL 9005Electrical properties:Nominal voltage:up to 1,0 mm²: U 0/U 300/500 Vstarting at 1,5 mm²: U 0/U 450/750 VTest voltage: 3000 V ACMechanical and thermal properties:Min. bending radius: flexing: 10 x cable thicknessTemperature range:up to 1,0 mm²:flexing: 0 °C up to +70 °C max. conductor temp.starting at 1,5 mm²:flexing: -15 °C up to +70 °C max. conductor temp.Flammability:flame retardant acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2Tests: acc. to EN 50395, EN 50396EC directive:This cable is conform to ECDirectives 2006/95/EC (Low Voltage Directive),ECD 2002/95/EC and 2011/65/EU (RoHS, Restriction of the use of certainhazardous substances).
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: gray
Thanks to the use of cross-linked special elastomer mixtures in the core insulation and the outer sheath, TITANEX® rubber sheathed cables impress with their extreme flexibility and suppleness, despite the highest mechanical and thermal resilience. They are UV and ozone resistant and are particularly suitable for permanent outdoor installation. According to DIN VDE 0298-300 (HD 516 S2), these H07RN-F rubber hose lines for heavy loads may also be briefly immersed in water.Number of cores x conductor cross-section: 5G2.5Outer Ø: 17.0 mmCable color: blackCopper weight: 120 g/mWeight: 0.3kg/mconstructionConductor structure: bare copper strands, finely stranded according to IEC 60228, class 5insulation: specially cross-linked elastomer EI4 according to DIN VDE 0281-1 (HD22.1)core identification:5 cores: green-yellow, brown, blue, black and greyOuter jacket: cross-linked elastomer with high mechanical strength propertiesmechanicsminimum bending radius:routed: 3x outer diametermobile operation: 6x outer diametertemperature range:installed: -60°C / +85°Cmobile operation: -25°C / +65°COzone resistance of the insulating sleeve: according to EN 60811-2-1 art. 8thoil-resistant: according to EN 60811-2-1electricsrated voltage [Uo/U]: 450/750 V600/1000 V with protected and fixed installationtest voltage: 2500 V
Datenleitung Niederfrequenz für Anwendungen als Steuer- und Signalleitung der Elektronik für Rechenanlagen, elektronische Steuer- und Regelgeräte, Büromaschinen, Waagen ...LiYY Datenleitungen haben trotz hoher Aderzahlen geringe AußendurchmesserAder-Farbcode nach DIN 47 100, ohne FarbwiederholungFlammwidrig nach IEC 60332 1-2Litzenleiter aus blanken KupferdrähtenPC-Aderisolation und AußenmantelAdern in Lagen verseiltFarbe: kieselgru (ähnlich RAL 7032)
DMX combination cable with 3x1,5 mm² power supply cable and 2x balanced LF cable (110 Ohm-capable) ideal for connecting all active cabinets or for parallel control of light mixers via mains cable and DMX signal via a cable Very flexible and resistant to crushing thanks to the cotton rounder And viscose very good pairwise shielding by tin-plated Cu spiral spiralTechnical specificationsPVC sheath diameter 14.5 mmNumber of inner conductors 2x 2x 0.14 mm²Diameter of mains cable 7.0 mmDiameter of signal line: 3,8 mmCu braid per wire (mains) - 56x0.15 mm Cu braid per wire (data) - 28x0.10 mmShielding data - cross braid,Tinned Cover (audio) - 90%Temperature range - -30 ° C to + 70 ° CFire load per m - 0,64 kWhWeight at 1m - 222g
Ölflex Classic 110 Black 0,6/1 kV 14G2,5This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: black
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: black
Datenleitung Niederfrequenz für Anwendungen als Steuer- und Signalleitung der Elektronik für Rechenanlagen, elektronische Steuer- und Regelgeräte, Büromaschinen, Waagen ...LiYY Datenleitungen haben trotz hoher Aderzahlen geringe AußendurchmesserAder-Farbcode nach DIN 47 100, ohne FarbwiederholungFlammwidrig nach IEC 60332 1-2Litzenleiter aus blanken KupferdrähtenPC-Aderisolation und AußenmantelAdern in Lagen verseiltFarbe: kieselgru (ähnlich RAL 7032)
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: gray
High flexible string line (ÖFLEX-FD production line with UL- and CSA-AWM approbation for the europe and north american market). For internal or external electronic cabling and electronic equippment on middle mechanic useage in dry or wettish rooms.
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: gray diameter 13mm
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: gray
Datenleitung Niederfrequenz für Anwendungen als Steuer- und Signalleitung der Elektronik für Rechenanlagen, elektronische Steuer- und Regelgeräte, Büromaschinen, Waagen ...LiYY Datenleitungen haben trotz hoher Aderzahlen geringe AußendurchmesserAder-Farbcode nach DIN 47 100, ohne FarbwiederholungFlammwidrig nach IEC 60332 1-2Litzenleiter aus blanken KupferdrähtenPC-Aderisolation und AußenmantelAdern in Lagen verseiltFarbe: kieselgru (ähnlich RAL 7032)
Small but mighty...because the SC-MONOMAX largely corresponds to a single cable, as can be found in the multi-coaxial cable TRANSIT MINI FLEX. It has dense shielding (95% Cu braiding) and the same flexible stranded structure, which makes it the perfect patch cable (e.g. for switch cabinet construction). It is assembled with conventional 75 O BNC connectors BNC0.3/1.8. It is available in RGBHV colors (red, green, blue, white and black). The maximum transmission length for these patch cables is around 30-50 meters, depending on the application.Advantages:Available in five colorsExcellent shielding thanks to tight copper braiding (95%)Very reliable and with the tightest tolerances in wave impedance (±3%)Compact due to small outer diameterLow damping values ??despite the miniature designUse:As a flexible video cable for control cabinet constructionFor asymmetrical internal wiringName: SC MonomaxProperties: OFC high purity copperProperties: analogFeatures: Digital 75 OField of application: studio / broadcastField of application: installationApplication: video cableColor: BlackColor detailed: blackStructure: LI2Y0.32mm(ST)CYSheath Material: Antistatic PVCSheath Ø [mm]: 2.70Number of channels (video): 1Inner conductor (video): 1Inner conductor (video) [mm²]: 0.08Inner conductor Ø (video) [mm]: 0.32AWG (video): 28Screening: tinned copper braidcoverage, opt. [%]: 95Cu strands (video): 7Cu strand Ø (video) [mm]: 0.12Conductor insulation material: Foam / Skin-PEConductor insulation Ø [mm]: 1.60Weight at 1 m [g]: 11Fire load per m [kWh]: 0.27Design: roundForeshortening factor: 0.8Minimum temperature [°C]: -25Maximum temperature [°C]: 70Width [mm]: 2.7Height [mm]: 2.7Capacity wire/screen at 1m (video) [pF]: 56Capacitance core/screen at 1 ft. (video) [pF]: 17.0688Attenuation at 5 MHz (100m & 20°C) [dB]: 4.3Attenuation at 5 MHz (100 ft. & 20 °C / 68 °F) [dB]: 1.3106Attenuation at 50 MHz (100m & 20° C) [dB]: 15Attenuation at 50 MHz (100 ft. & 20 °C / 68 °F) [dB]: 4.572Attenuation at 100 MHz (100m & 20°C) [dB]: 21.5Attenuation at 100 MHz (100 ft. & 20 °C / 68 °F) [dB]: 6.5532Attenuation at 1485 MHz (100m & 20°C) [dB]: 94.5Attenuation at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB]: 28.8036Attenuation at 3000 MHz (100m & 20° C) [dB]: 148Attenuation at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB]: 45.1104Wave impedance [O]: 75Return loss [dB]: 20BPVO Euroclass: Fca
This cable is ideal to built up a contolling or connecting line. The line is used in dry, wettish or wet rooms on normal mechanical use. In cause of longtime outside useage you will need an UV protection, flame retardant line IEC 332.1, PVC-cladding: gray
€3.60*
Immediately available or ready for collection
This website uses cookies to ensure the best experience possible. More information...